Insulation Code | Insulation Type | Appearance | Insulation Temperature Range* | Abrasion Resistance | Flexibility | Water Submersion | |
---|---|---|---|---|---|---|---|
Overall | Conductors | ||||||
HH |
High Temp |
High Temp |
-73 to 704°C |
Poor |
Good |
Poor |
|
XR |
Refrasil Braid |
Refrasil Braid |
73 to 871°C |
Poor |
Good |
Poor |
|
XC |
Nextel Braid |
Nextel Braid |
-17 to 1204°C |
Fair |
Good |
Poor |
Insulation Code | Resistance To: | Comments | ||||
---|---|---|---|---|---|---|
Solvent | Acid | Base | Flame | Humidity | ||
HH |
Excellent |
Excellent |
Excellent |
Excellent |
Fair |
High Temp. Glass Braid Over Each Conductor, and Binder Impregnated.
Overall High Temp Glass Braid Applied and Bindered. |
XR |
Excellent |
Good to 316°C (600°F) |
Good to 316°C (600°F) |
Excellent |
Poor |
Braid of Vitreous Silica Fibre Applied to Each Bare Wire.
Then Over Both. Suitable to 982°C (1800°F) if Not Subjected to |
XC |
Excellent |
Good |
Good |
Excellent |
Fair |
High Temp. Alumina-Boria-Silica Ceramic Fibre Braided Over Each Conductor Then Over Both. Not Recommended for Platinum Thermocouples or Exposure to Molten Tin and Copper, Hydrofluoric or Phosphoric Acids, or Strong Alkalies. |
Telephone: 44 (1455) 285520 |